Civil Defence Approved · Kingdom of Bahrain

Fire Suppression Systems in Bahrain

Fire Suppression Systems in Bahrain

Gas-based and clean agent suppression for critical rooms, plus kitchen hood fire suppression for commercial kitchens.

Fire suppression

Protection where water is not the answer

Some spaces cannot be protected with water alone. Server rooms, data centres, electrical and control rooms, telecom rooms, archives and commercial kitchens need a suppression system that puts out a fire quickly without damaging equipment or spreading burning oil.

FST supplies, installs, tests and maintains fire suppression systems in Bahrain. Each system is selected to suit the protected room, the hazard, the room volume and integrity, and the approved project design, and is linked to detection and the fire alarm system.

Clean agent fire suppression cylinders in a data centre
Kitchen hood fire suppression nozzles

Gas-based suppression

Clean agent & gas suppression systems

Agent selection depends on the hazard, room size, occupancy and project specification. Final system design should be confirmed for each project.

FM-200 (HFC-227ea)

Clean agent that suppresses fire within seconds, leaves no residue and is widely used for server and electrical rooms.

Novec 1230 (FK-5-1-12)

Clean agent with a low environmental impact, suitable for occupied spaces and sensitive equipment.

CO₂ Systems

Carbon dioxide systems for unoccupied or normally unoccupied hazards such as plant rooms, generators and machinery spaces.

Inert Gas Systems

Inert gas blends that reduce oxygen to a level that stops combustion, with no residue and no ozone impact.

Aerosol Systems

Compact aerosol generators for electrical cabinets, panels and small enclosed spaces.

Detection & Release Control

Detectors, release panels, abort and manual release stations, alarms and signage linked to the fire alarm system.

  • Server & data rooms
  • Electrical & control rooms
  • Telecom rooms
  • Archives & record stores
  • Generator & plant rooms
Kitchen hood fire suppression system in a commercial kitchen

Commercial kitchens

Kitchen Hood Fire Suppression System

Cooking oil and grease fires spread fast through hoods and exhaust ducts, and water can make them worse. A kitchen hood fire suppression system uses a wet chemical agent that knocks down the flames and cools the oil to stop re-ignition.

  • Nozzles over each fryer, range, griddle and grill, plus the hood plenum and exhaust duct
  • Automatic detection with fusible links or heat detectors, plus a manual pull station
  • Automatic gas / power shut-off and connection to the building fire alarm
  • For restaurants, hotels, cafeterias, hospitals and central kitchens
  • Supply, installation, testing and periodic servicing
Enquire About Kitchen Hood Systems

Scope of work

From survey to maintenance

  1. 01

    Site Survey & Design

    Hazard review, room volume and integrity, agent selection.

  2. 02

    Supply & Installation

    Cylinders, pipework, nozzles, detection and release panels.

  3. 03

    Testing & Commissioning

    Room integrity, function and interface testing.

  4. 04

    Maintenance

    Periodic inspection, weighing and servicing of cylinders.

FAQ

Frequently Asked Questions

Can’t find what you need? Our team will review your project details and guide you on the next step.

Ask our team

Which rooms need a gas-based fire suppression system?

Typically server and data rooms, electrical and control rooms, telecom rooms, archives and other spaces with valuable or water-sensitive equipment. The requirement depends on the project design and authority approval.

Is FM-200 or Novec 1230 safe for occupied rooms?

Both are clean agents designed for normally occupied spaces when the system is designed to the correct concentration. CO₂ systems are generally used only for unoccupied hazards.

Does a commercial kitchen need a hood suppression system?

Commercial kitchens with hoods over cooking appliances usually require a kitchen hood fire suppression system. Share your kitchen layout and equipment list so the team can review the requirement.

Do you maintain existing suppression systems?

Yes. Contact FST with the system type, agent, number of cylinders and location to arrange inspection and maintenance.

Need a Fire Suppression System in Bahrain?

Talk to FST about gas-based suppression for critical rooms or kitchen hood fire suppression for your commercial kitchen.

WhatsApp us